Used 12,300 Sq. Ft. Horizontal CS Heat Exchanger. CS Shell rated 250 PSI @ 200 Deg F. CS tubes rated 150 PSI @ 150 deg. F. Shell: 4' 1" dia. (2238) 3/4" dia tubes X 28' L. Split Flow Pass Shell; 2 Pass Tubes. Nozzles: Shell - (2) 6"; Tubes - (4) 14". Built by Yuba, 1993. S/N: 93-B104-1, NB# 6307. Previous use: Chiller. U-1 on file.
Used 9161 Sq. Ft. Vertical CS Heat Exchanger. CS Shell with expansion joint rated 389 PSI @ 482 Deg F. CS tubes rated 2321 PSI @ 150 deg. F. Shell: 5'8" dia x 38'4" L. 1400 Tube Holes - 1.22" dia tubes X 20' L. 6 Pass Shell; 2 Pass Tubes. Built by Schoeller-Bleckmann Nooter, 1997. S/N: 8182, NB# 70. Previous use: UREA H.P. STRIPPER. Drawing and U-1 on file.
Unused 8164 sq ft shell and tube heat exchanger. Manufactured by SteelTek. Type BKM. Size 38/54-396. (1548) .625" OD SA-214 Tubes rated 1200 PSIG@200F. SA-516 Shell rated 300PSIG@200F. (2) Saddle mounted. 41'OAL x 55.25"OD x 4'6"OAH. National Board #2438. Serial #12S-2783. Built 2012. 50000lb. Designed as Second Gas Chiller.
Unused 7778 Sq Ft Carbon Steel Horizontal Shell and Tube Heat Exchanger. Manufactured by FABSCO. Shell rated 350PSIG@250F. (1531) 1"OD Tubes rated 250PSIG@250F. Serial #S07-9577-12. National Board #5193. Built 2007.
Used 7135 Sq Ft horizontal shell & tube heat exchanger, U-Tube. CS shell rated 150 PSI @ 250 degrees F. (1312 Tube holes) 3/4" CS tubes rated 200 PSI @ 200 degrees F. Shell dia: 4'5" OD, OAL: 35'. Shell nozzles: 18", 8", 3", Tube nozzles: (2) 10", CS Heads. No of Baffles: 6, TEMA Type: BKU, (2) saddle supports. Mfg by Exchanger Repair Inc, 1991. Previous Use: Reboiler. U-1 & drawing on file.
Used 3917 sq.ft. Shell and Tube Heat Exchangers. Carbon Steel Shell Rated 300 PSI @ 532 deg.F. (1147) 3/4 x 18' Carbon Steel tubes rated 300 PSI @ 532F. Type BEM. QTY (4) available.
Used Approx 3,851 Sq Ft Carbon steel vertical shell and tube heat exchanger. CS shell rated 316 PSI @ 470 deg F. CS Tubes rated 75 PSI @ 900 deg F. Shell: 38" OD x 20' L, (739) tubes, 1" OD x 239"L. 300#, Flange Nozzles: (1) 10", (1) 6", (1) 3", (2) 2", (1) 1". 1 Pass Shell, 1 Pass Tubes. Built 1992 - Atlas Industrial Manufacturing Co. National Board # 6896, Serial # 8233. Re-Built in 1998 by Exell, Inc., S/N: 13345, NB # 1865. Unit has expansion joint. Weight - Approx. 19,750 #.
Used 3654.5 Sq Ft Energy Exchanger Company Carbon Steel Vertical Shell & Tube Heat Exchanger. Shell rated 240 psig @ 550 F, Tubes rated 240 psig @ 420 F, Type AEL, Size 49 x 144. (1551) Tubes x 3/4" ID x 14 ga x 12' Lg. Shell Dimension: 4' 2 1/2" ID x 12' Lg. Lug Mounted, Serial #X-1168B, National Board #291, Built 1980. Previous Use: Ethylene Oxide.
Used 3654.5 Sq Ft Energy Exchanger Company Carbon Steel Vertical Shell & Tube Heat Exchanger. Shell rated 240 psig @ 550 F, Tubes rated 240 psig @ 420 F, Type AEL, Size 49 x 144. (1551) Tubes x 3/4" ID x 14 ga x 12' Lg. Shell Dimension: 4' 2 1/2" ID x 12' Lg. Lug Mounted, Serial #X-1168A, National Board #287, Built 1980. Previous Use: Ethylene Oxide.
Used 3317 Sq Ft Slagle Manufacturing Carbon Steel Vertical Shell & Tube Heat Exchanger. Shell rated 240 psig @ 350 F, Tubes rated 240 psig @ 530 F, Size 40-168, Type BEM-EJ. Tubes (1253) x 3/4" ID x 14 ga x 14' Lg. Shell 41" ID x 14' Lg. Slagle Serial #34983-1, Built 1983. Certified by Roark Enterprises in 1989, Serial #89-545-2, National Board #701. Estimated Weight -- 24,600#. Previous Use: Ethylene Oxide.
Used 3140 Sq Ft Carbon Steel Shell and Tube Heat exchanger. Manufactured by GEO Heat Exchangers LLC. (400) .75"OD Carbon Steel tubes MAWP 1265 PSI@ 400F. Shell MAWP 1265PSI@400F. National Board #549. Serial #10810B. Built 2010.
Used Cust-O-Fab U Tube Shell & Tube Heat Exchanger. Approximate 3090 Square Feet. Carbon steel shell rated 1715 psi at 610 degrees F. (295) 1" diameter x 20' long SA-213-T11 Chromium-molybdenum steel tubes rated 2184 psi at 750 degrees F. Serial# 97-202. National Board# 4666. Built 1997.
Unused 2882 Sq Ft Shell and Tube heat exchanger. Manufactured by Apex Engineered Products. Carbon Steel Shell rated 1685PSI @ 625F. (735) 1"OD x 180"L SA-213-T11 Carbon Steel Tubes rated 485PSI @ 835F. Alloy 625 Toroidal Expansion Joint. National Board #235. Serial #C-1275. Built 2018. Designed as a effluent waste heat boiler.
Unused 2839 Sq Ft Carbond Steel Horizontal Shell and Tube Heat Exchanger. Manufactured by FABSCO. Shell Rated 1000PSIG@250F. (745) .75"OD Tubes rated 250PSIG@250F. Serial #S07-9577-5. National Board #5190. Built 2007.
Unused 2589 sq. ft. Horizontal U-tube Heat Exchanger. Mfr Ohmstede Ltd. Carbon steel shell rated 1080 psi @ 570°F. (480) 1" diameter X 11' long 321 stainless steel tubes rated 866 psi @ 645°F. Size 49-132, type AEU. National Board #3704. Serial #748954. Built 2010.
Unused 2589 sq. ft. Horizontal U-tube Heat Exchanger. Mfr Ohmstede Ltd. Carbon steel shell rated 1080 psi @ 570°F. (480) 1" diameter X 11' long 321 stainless steel tubes rated 866 psi @ 645°F. Size 49-132, type AEU. National Board #3704. Serial #748954. National Board #3703. Serial #748953. Built 2010.
Used 2530 Sq Ft Roark Enterprises Carbon Steel Horizontal Shell & Tube Heat Exchanger. Shell rated 75 psig @ 150 F, Tubes rated 75 psig @ 150 F, mounted on 2 saddles. (806) Tubes x 3/4" OD x 16' L x 0.085" ga. Serial #93440, National Board #334, Built 1993. Previous Use: Ethylene Oxide.
Used 2467 Sq Ft Merrick Mechanical Carbon Steel Horizontal Shell & Tube Heat Exchanger. SA-516-70 Shell rated 75 psi @ 150 F, -20 F @ 75 psi. Tubes rated 75 psi @ 150 F, -20 F @ 75 psi. (806) SA-214 Tubes x 3/4" OD x 14 ga x 15' 6" Lg. Mounted on 2 saddles, Serial #184, National Board #94, Built 1992. Previous Use: Ethylene Oxide.
Used 2311 Sq Ft Horizontal U-Tube Heat Exchanger. Manufactured by Steeltek. Type BEU. Size 27-240. Carbon steel shell rated 312 psi/Full Vacuum @ 400 F. (302) .75" Diameter x 20' long carbon steel tubes rated 307 psi/Full Vacuum @ 400 F. Carbon steel tubesheet and head. Openings shell: (2) 12", tubes (2) 8". Saddle mounted. Serial # 08S-2414. National Board # 2020. Built 2009.
Unused 2139 Sq. Ft. CMS Heat Transfer Division Carbon Steel shell and tube heat exchanger. CS Shell rated 1585 psi @ 130F. (227) 1” Carbon Steel tubes rated 1100 psi @ 175F. Serial# 1913.3. National Board# 761. Built 2007.
(1) Used 1964 Sq. Ft. Superior Hardsurfacing Co, Inc Vertical Carbon Steel Shell & Tube Heat Exchanger (Type BEU). Shell rated 321 PSI @ 465°F; Tubes rated 126 PSI @ 850°F. Tubes (295) 1"O.D. 19' Overall length x 44" O.D. (1)" Inlet; (1) 8" Outlet; (1) 6" Inlet; (1) 12" Outlet; (1) 1" Blowdown; (1) 2". Clean. Weight 18,000 lbs. Built 1997. Serial # 97-22080; National Board # 1191.
UNUSED Gaspar Inc. approximately 1,768 square foot Shell and Tube Heat Exchanger. 24” diameter X 19’ 4” face to face length. Carbon steel shell rated 604 PSI @ -20 to 455 degrees F. (466) 3/4” SA179 carbon steel tubes rated 600 PSI @ -20 to 455 degrees F. National Board# 2812, S/N 37317-2. 6” Process, 6” Service nozzles. Built 2010.
Unused 1736 Sq Ft Carbon Steel Horizontal Shell and Tube Heat Exchanger. Manufactured by FABSCO. Shell Rated 275 PSIG@250F. (376) 1"OD Tubes rated 240PSIG@250F. National Board #5204. Serial #S07-9577-2. Built 2007.
Unused 1280 sq ft (119m2) K°Flex 316Ti Stainless Steel Shell and Tube plate exchanger. Mfg Kelvion GmbH. Tube side rated 1 bar @550 C (14.5 PSI@ 1022F), shell rated 7 bar @550 C (101PSI@1022F). Overall 4490mm x 400mm x 980mm. Dry weight 4300 kg. Serial #654-15-002. Built 2018.
Unused 1103 Sq. Ft. CMS Heat Transfer Division Carbon Steel Shell and Tube Heat Exchanger. Shell Rated 550PSI@250F. (117) 3/4” U tubes rated 150PSI @600F. Serial# 1913.2. National Board #760. Built 2007.
Unused 996.8 Sq. Ft. Fintube carbon steel heat exchangers. Mfg Brown. 3/4” Carbon Steel U tubes 1440 psi @ 130F on both shell and tubes. National Board stamp. Serial #06086-05-1-02A. Built 1996.
Unused 996.8 Sq. Ft. Fintube carbon steel heat exchangers. Mfg Brown. 3/4” U tubes 1440 psi @ 130F on both shell and tubes. National Board stamp. Serial #06086-05-1-02B. Built 1996.
Unused 996.8 Sq. Ft. Fintube carbon steel heat exchangers. Mfg Brown. 3/4” U tubes 1440 psi @ 130F on both shell and tubes. National Board #17728. Serial #06086-05-1-02. Built 1996.
Unused 996.8 Sq. Ft. Fintube carbon steel heat exchangers. Mfg Brown. 3/4” U tubes 1440 psi @ 130F on both shell and tubes. National Board #17727. Serial #06086-05-3-01. Built 1996.
Unused 693 square foot Shell and Tube Heat Exchanger. Fabricated by Gaspar Inc. 26” diameter X 6’ 5” face to face length. Carbon steel shell rated 614 PSI @ -20 to 450 degrees F. (551) 3/4” SA179 carbon steel tubes rated 611 PSI @ -20 to 450 degrees F. 12” Process, 6” Service nozzles. National Board# 2829, S/N 37318-1. Built 2010.
Unused 693 square foot Shell and Tube Heat Exchanger. Bulit by Gaspar Inc. 26” diameter X 6’ 5” face to face length. Carbon steel shell rated 614 PSI @ -20 to 450F. (551) 3/4” SA179 carbon steel tubes rated 611 PSI @ -20 to 450F. 12” Process, 6” Service nozzles. Insulated. National Board# 2830. Serial #37318-2. Built 2010.
Used 500 sq. ft. vertical heat exchanger. Mfg. by Energy Exchanger Company in 2012. TUBES: 14' L x 0.75" Dia, 320 psig/FV at 385 F, tube holes 185, tube wall 0.083", carbon steel. SHELL: 1'4" Dia, carbon steel, 455 psig/FV at 515 F. S/N: X-7926. NB# 6052. Previous Service: Wastewater Ammonia Purifier Reboiler.
Unused Koch 358 sq. ft. Separated Closure Hairpin Heat Exchanger. Model 12144-MTB-ABC. Carbon steel shell and tube 12" diameter X 144" long tube length. Shell rated 695/FV @ 400F. Tube side 75/FV @400F. Designed for shell side split flow with each leg in parallel. Cast removable housing cover on hairpin. Designed U-tube with floating head. Serial #10662-08-1-01. Built 2008.
Used vertical 318 Sq Ft Shell & Tube Heat Exchanger. CS Shell rated 515 PSI @ 550 deg F. CS Tubes rated 90 @ 370 deg F. 18" Shell x 10' L. (OAL - 13' 10"). (126) 1" OD Tubes x 10' L. Nozzles: Shell - 4" inlet, 2" outlet; Tubes - 6" inlet, 10" outlet. 1 Pass Shell, 1 Pass Tubes. Built by Energy Exchanger, 1981. S/N: x-1252, NB# 376. Weight: 4500 lbs. Previous Use: Ammonia Stripper Reboiler.
UNUSED KOCH 268 SQUARE FOOT SEPARATED CLOSURE HAIRPIN HEAT EXCHANGER. CARBON STEEL SHELL AND TUBE, 12" DIAMETER X 96" LONG TUBE LENGTH. RATED 1000/PSI FV AT 365 DEGREES F SHELL AND TUBE SIDE. HAIRPIN HAS A CAST REMOVABLE HOUSING COVER. REMOVABLE TUBE BUNDLE. DESIGNED WITH U-TUBE WITH FLOATING HEAD. MODEL 12096-MTB-AAC. YEAR 2008.
Used 39 Sq Ft Doyle and Roth Horizontal Carbon Steel Shell and Tube Heat Exchanger. Shell rated 150PSI/FV @ 500F. (20) .75"OS x 10'L tubes rated 150PSI/FV @ 400F. Approximately 25" OAH x 141" OAL. Weight 1,220 lbs. Serial #S2777-3. National Board #21585. Built 2015.
UNUSED approx. 25 Sq Ft Carbon Steel Heat Exchanger. Shell Rated 250 PSI @ 212 deg F; Tubes rated 250 PSI @ 212 deg F. Shell: 7" OD x 60" L (77" OAL) (24) 3/4" dia Straight tubes. Nozzles: (4) 2". Built by Weldon, 1985, S/N: 3366, NB# 3791.